Vents
Extractor fan Arc White 125
nominal size: 125 mm
wattage: 2.9 W
max. airflow: 140 m³/h
IP44 protection against splashing water
timer, temperature sensor, motion sensor, humidity sensor, light sensor
Item number Arc-125
immediately ready for dispatch, delivery time 2 - 3 days
* Incl. VAT excl. Shipping
Dimensions and technical details
- 100-240 V ~ 50/60 Hz
- Housing colour: white
- Housing material: UV-resistant ABS
- Nominal diameter: 125 mm
- Bearing: ball bearing
- Speed levels: 5
- Wattage: 0.4 / 0.6 / 0.8 / 1.6 / 2.9 W
- Current consumption: 0.018 / 0.019 / 0.021 / 0.029 / 0.04 A
- Airflow rate: 20 / 40 / 60 / 90 / 140 m³/h
- Sound pressure level Lp-3m: 9 / 13 / 18 / 22 / 28 dB(A)
- IP rating: IP44
- Diameter housing: 193 mm
- Diameter duct connection: 125 mm
- Depth: 55 mm
- Total depth: 81 mm
- Weight: 0.5 kg
- Thermal overload protection
- Mounting options: wall, ceiling
- Application: direct connection to the ventilation shaft
- Operating mode 1: Continuous ventilation at speed 1; if the motion/light sensor is triggered, change to speed 3; if the humidity sensor is triggered, change to speed 4.
- Operating mode 2: Continuous ventilation at speed 2; if the motion/light sensor is triggered, change to speed 3; if the humidity sensor is triggered, change to speed 4.
- Operating mode 3: Continuous ventilation at speed 2; if the humidity sensor is triggered, change to speed 5.
- Operating mode 4: Continuous ventilation at speed 3; if the humidity sensor is triggered, change to speed 5.
- Operating mode 5: Standby operation; if the motion/light sensor is triggered, change to speed 3; if the humidity sensor is triggered, change to speed 4.
- Operating mode 6: Intermittent ventilation (30 minutes every 12 hours) at speed 1; if the motion/light sensor is triggered, change to speed 3; if the humidity sensor is triggered, change to speed 4.
- Operating mode 7: Standby operation; if the temperature sensor is triggered, change to speed 4. Switches on at 28°C in the room, switches off at 24°C.
- Operating mode 8: Standby operation; if the humidity sensor is triggered, change to speed 5.
- If one or more sensors are triggered, the fan switches to high speed and runs until the sensor signal disappears. After the sensor signal disappears, the fan continues to run at high speed for another 15 minutes and then switches to standard operation. If a motion sensor or a light sensor is triggered, the fan switches to high speed with a delay of 30 seconds to prevent the fan from switching on when someone is in the room for only a short time.
tab placehold
webtotrade GmbH
Käthe-Kollwitz-Str. 22
04600 Altenburg
Germany
info@creoven.com
+4934478438000